didoEASY M / didoEASY+ M / didoEASY++ M
Since the meters do NOT require any pre-setting procedure, measurement results are acquired very quickly:
1. Position the detector and switch on the didoEASY meter...
2. Set the x-ray equipment to the desired parameters...
3. Expose... - and simply read all measurement information from the meter‘s display. The QUART didoEASY M meters automatically compensate for Mo/Mo beam quality. Corrections factors are provided for further radiation qualities.
Technical specifications
General Features
- Exposures: one to acquire all parameters
- Mode: auto-start, auto-stop & auto-reset
- Power supply: Rechargeable Li Ion accu
- Battery time: approx. 120 hrs. until recharge required
- Base size: 17x7x4.5cm (LxWxH)
- Base weight: 200 g
- Detector size: 6.0x1.8x0.5cm (LxWxH)
- Detector weight: negligible (!)
Specifications
didoEASY M - basic configuration
- Dose: 0.99 µGy – 999 mGy (Uncertainty: ±5% @ 25-40 kV / Resolution: 0.01 µGy)
- Dose Rate: 0.5 µGy/s – 999 mGy/s (Uncertainty: ±5% @ 25-40 kV / Resolution: 0.1 µGy/s)
- Time: 1.0 ms - 296 s (Uncertainty: ±1.4 ms / Resolution: 0.1 ms)
didoEASY+ M - features added kV measurement
- Dose: 0.99 µGy – 999 mGy (Uncertainty: ±5% @ 25-40 kV / Resolution: 0.01 µGy)
- Dose Rate: 0.5 µGy/s – 999 mGy/s (Uncertainty: ±5% @ 25-40 kV / Resolution: 0.1 µGy/s)
- Time: 1.0 ms - 296 s (Uncertainty: ±1.4 ms / Resolution: 0.1 ms)
- Pulses: 1 - 9999 (Uncertainty: ± 1 pulse)
- Pulse Rate: 0.1 - 250 pulses/s (Uncertainty: ± 0.1 pulses/s)
- kVp / PPV: 25 – 35 kV (Uncertainty: ±5% at calibrated reference points / Resolution: 0.1 kV); Exposure conditions: Mo/Mo; HVL 0.2 – 0.45 mm Al eq., correction factors provided for further radiation qualities
didoEASY++ M - features added kV and direct-HVL measurement
- Dose: 0.99 µGy – 999 mGy (Uncertainty: ±5% @ 25-40 kV / Resolution: 0.01 µGy)
- Dose Rate: 0.5 µGy/s – 999 mGy/s (Uncertainty: ±5% @ 25-40 kV / Resolution: 0.1 µGy/s)
- Time: 1.0 ms - 296 s (Uncertainty: ±1.4 ms / Resolution: 0.1 ms)
- Pulses: 1 - 9999 (Uncertainty: ± 1 pulse)
- Pulse Rate: 0.1 - 250 pulses/s (Uncertainty: ± 0.1 pulses/s)
- kVp / PPV: 25 – 35 kV (Uncertainty: ±5% at calibrated reference points / Resolution: 0.1 kV); Exposure conditions: Mo/Mo; HVL 0.2 – 0.45 mm Al eq., correction factors provided for further radiation qualities
- Direct-HVL: 0.2 – 0.45 mm Al (HVL output, Uncertainty: ±10% / Resolution: 0.1 mm Al); Internal filtration Mo/Mo; 25-35 kV
* S A Mitchell and C J Martin, Comparison of ionisation chamber and semiconductor detector devices for measurement of the dose–width product for panoramic dental units, J. Radiol. Prot. 33 321 (2013).